If it says the code was invalid, then the default failed to go through. If the system displays "Enter Section", then the factory default was successful. The screen will display "Enter Your Installers Code". It the default failed, repeat the process and try again.Īn easy way to check if the default went through is to try using the default Installer Code to access programming. If it has, reconnect the backup battery, and close the panel. Check and confirm that the system has been restored to its factory default settings. This should factory default the system.Ĥ. Then unplug the transformer to power the system back down. Plug in the AC transformer to power the system back on. These inputs are shown in the picture below:ģ. Connect a jumper between inputs IO1 and IO2. Then unplug the AC transformer from the wall outlet. Disconnect the backup battery by unplugging it. Then carefully separate the front of the panel from the back. To do this, use a small screwdriver to press in the two bottom tabs on the front of the panel. Start by opening up the DSC Impassa System. All zones that have been set up with the system will need to be reprogrammed, and all sensors will need to be relearned.Ĭomplete the following steps to perform a factory default on a DSC Impassa Alarm System:ġ. It will also restore the Master Code to 1234 and the Installer Code to 5555. Performing a factory default will restore all system settings to their default. Then disconnect the jumper, and power the system back on. Power up the panel, wait 10 seconds and power down. Then connect a jumper between inputs IO1 and IO2. The tabs on the front should click into place.You can reset a DSC Impassa to factory defaults by first unplugging the AC transformer and disconnecting the battery to cut power. Make sure that both ends are securely closed. Then close the lower portion with the tabs. When doing this, the top portion of the system (opposite from the tabs) should be closed first. Close the front of the system to its back. Then re-secure the battery tab using the screwdriver.Ĥ. Plug the cable attached to the battery into the same plug-in on the board that the old battery was using. Slide the new battery into the place of the old one. The picture below shows the battery plug and the battery tab:ģ. With the tab released, the old battery can be taken out from the system. Then use a Phillips screwdriver to unscrew the tab holding the battery in place. Unplug the battery from the board on the system. The two tabs on the front of the panel can be seen in the picture below:Ģ. Push both the tabs in, and then pull the front of the system away from the back to open it up.
ADT CONTROL PANEL SCW9057G BRIGHTNESS UPGRADE
Remote firmware upgrade via cellular/internet. 2-way is available only on IMPASSA 9057 Self-Contained Wireless Security Systemt. The tabs can be pushed in using a small screwdriver or other sturdy thin object. Built-in 2-way audio VOX and push-to-talk alarm communication via phone line and cellular. On the front of the DSC Impassa System, there are two tabs that must be both individually pressed in before the system can be opened. Complete the following steps to change the battery in your DSC Impassa:ġ. It is necessary to replace the backup battery in a DSC Impassa every few years. You can change the battery in your DSC Impassa by opening up the system, unplugging the old battery, unscrewing the battery tab, pulling out the battery, inserting the new one, reapplying the battery tab, plugging in the new battery and finally closing the DSC Impassa Alarm System.